Product description
Tee joints have large surface area and often leave gaps when insulated with sheet material or fixed metal cladding. Type T combines thin Aerogel, aluminum-laminated fiberglass and a pattern shaped around the main run and branch to improve thermal retention in congested spaces.
Suitable for tee joints, steam/thermal branch nodes and tight pipe zones.
Aerogel core reduces thickness while maintaining strong insulation performance.
Stainless snap locators help prevent closure straps from slipping across repeated removals.
Reduces gaps around the main run and branch, limiting heat loss at division nodes.
Detailed technical specifications
Detailed technical specifications
| Brand | Flexinsul Jacket |
|---|
| Designed for | Tee Joints and Pipe Branch Connections |
|---|
| Size | DN15 | DN20 | DN25 | DN32 | DN40 | DN50 | ... | DN300 | Other |
|---|
| Material options | Rockwool | Ceramic | Aerogel | Silica | Other based on survey |
|---|
| Density | 80 kg/m³ | 96 kg/m³ | Other |
|---|
| Standard thickness | 25mm | 50mm | 75mm | 100mm | Other |
|---|
| This type operating range | -30°C to 450°C |
|---|
| This type material setup | Aluminum laminated fiberglass with Nanogel Silica Aerogel |
|---|
| This type reference thickness | 20mm / 35mm |
|---|
| Energy saving | Up to 95% heat-loss reduction under suitable design conditions |
|---|
| Outer shell | Silicone-coated fiberglass cloth: water-resistant, heat-resistant, chemical-resistant |
|---|
| Sewing thread | SS Core Flame-Resistant Thread |
|---|
| Silicone shell temperature | Up to 260°C. Higher-temperature material options available |
|---|
The specifications above are for initial consultation. During actual implementation, Anton Therm adjusts the design by peak temperature, indoor/outdoor conditions, humidity, chemicals, vibration and removal requirements.
Required audit information
Survey information required
Overview and close-up photos of the component, including opening/removal direction for maintenance.
DN/key dimensions, length, bend radius, flange, nozzles or equipment geometry.
Normal operating temperature, peak temperature, pressure and heat-up/cool-down cycle.
Environment: indoor/outdoor, UV, steam, oil, chemicals, vibration and washdown.
Inspection, cleaning, bolt-tightening, drain or actuator/sensor removal frequency.
Acceptance criteria: target touch temperature, sealing, closure strength, reusability and finish quality.
If drawings are not available, Anton Therm can guide minimum measurement points or survey on site for pattern development.